Light Output for Room Lighting

Use illuminance target wey you choose find number of light fittings.

Add to workspace

Your numbers

Calculations dey happen locally. Results na estimates, no be professional advice.

Number of light fittings

—

Lumen-method estimate, no be lighting simulation. Glare, daylight, task position and electrical design need separate review.

Formula

Use N = ceil(AE/(Φum)). A na area for m², E na di illuminance wey you choose for lux, Φ na lumens per fixture, and u and m na utilization and maintenance factors. ceil dey round up to whole fixtures.

Use illuminance target wey you choose find number of light fittings.

Example wey show the calculation

Area wey need covering (m²)
20
Illuminance target wey you choose (lux)
300
Lumens wey one light fitting produce
1000
Factor for light utilization
0.6
Factor for light maintenance
0.8
Number of light fittings
13
Total installed lumens wey you need
12,500 lm

Where e fit work and limits

Lumen-method estimate, no be lighting simulation. Glare, daylight, task position and electrical design need separate review.

We check inputs for missing values and allowed ranges. Result wey pass the finite numeric range no go show. Rounding affect wetin display, while calculation use the model numeric precision.

Check your units and assumptions before you rely on result. Changing label no convert currency or physical unit.